  Datasheet File OCR Text:
 1.25 Gbps Single Mode Transceiver
C-13-1250AC-T(3)-SSC(2)
Features * SC Duplex Single Mode Transceiver * Industry Standard 1x9 Footprint * Gigabit Ethernet Compliant * Single +3.3V/+5V Power Supply * LVPECL Differential Inputs and Outputs (AC-coupling) * LVTTL Signal Detection Output * Wave Solderable and Aqueous Washable * Uncooled laser diode with MQW structure * Complies with Telcordia (Bellcore) GR-468-CORE * Gigabit Ethernet Application * RoHS compliance available
Absolute Maximum Rating Parameter Power Supply Voltage Power Supply Voltage Output Current Soldering Temperature Storage Temperature Symbol Vcc Vcc Iout
-
Min. 0 0 0 -40
Max. 3.6 6 30 260 85
Unit V V mA C C
Note C-13-1250AC-T3-SSC(2) C-13-1250AC-T-SSC(2) 10 seconds on leads only
Tstg
Recommended Operating Condition Parameter Power Supply Voltage Power Supply Voltage Operating Temperature1 Operating Temperature1 Data Rate Note1: Please refer to ordering information Symbol Vcc Vcc Topr Topr Min. 3.1 4.75 0 -40 Typ. 3.3 5 1250 Max. 3.5 4.25 70 85 Unit V V C C Mbps
LUMINENTOIC.COM
20550 Nordhoff St. * Chatsworth, CA 91311 * tel: 818.773.9044 * fax: 818.576.9486 9F, No 81, Shui Lee Rd. * Hsinchu, Taiwan, R.O.C. * tel: 886.3.5169222 * fax: 886.3.5169213
1
LUMNDS827-Jan0408 Rev A.1
1.25 Gbps Single Mode Transceiver
C-13-1250AC-T(3)-SSC(2)
Transmitter Specifications Parameter Optical Transmit Power Optical Transmit Power Output center Wavelength Output center Wavelength Output Spectrum Width Output Spectrum Width Extinction Ratio Output Eye Optical Rise Time Optical Fall Time Relative Intensity Noise Total Jitter Transmitter Specifications Parameter Power Supply Current Differential Data Input Voltage Symbol ICC VIH-VIL Min 650 Typical Max 180 2000 Unit mA mV Notes Maximum current is specified at Vcc= Maximum @ maximum temperature AC-coupled tr tf RIN TJ Symbol Po Po ER Min -10 -5 1270 1275 9 Typical 1310 1310 Max -3 0 1355 1350 4 2.5 0.26 0.26 -120 0.27 Unit dBm dBm nm nm nm nm dB ns ns dB/Hz ns Measured with 27-1 PRBS 20% to 80% Values 20% to 80% Values Notes C-13-1250AC-T(3)-SSC C-13-1250AC-T(3)-SSC2 C-13-1250AC-T(3)-SSC C-13-1250AC-T(3)-SSC2 RMS(), C-13-1250AC-T(3)-SSC RMS(), C-13-1250AC-T(3)-SSC2
Compliant with IEEE 802.3
Receiver Specifications Parameter Sensitivity2 Maximum Input Power Signal Detect-Asserted Signal Detect-Deasserted Signal Detect-Hysteresis Wavelength of Operation Note 2: Measured with 27-1 PRBS, BER= 10-12 Symbol Pin Pa Pd Min -3 -38 1 1100 Typical Max -24 -24 1600 Unit dBm dBm dBm dBm dB nm Measured on transition: low to high Measured on transition: high to low Notes
Receiver Specifications Parameter Power Supply Current Differential Data Output Voltage Signal Detect Output Voltage-Low Signal Detect Output Voltage-High Symbol ICC VOH -VOL VSDL VSDH Min 600 2.0 Typical Max 100 1600 0.5 Unit mA V V V AC-coupled LVTTL Output Note The current excludes the output load current
LUMINENTOIC.COM
20550 Nordhoff St. * Chatsworth, CA 91311 * tel: 818.773.9044 * fax: 818.576.9486 9F, No 81, Shui Lee Rd. * Hsinchu, Taiwan, R.O.C. * tel: 886.3.5169222 * fax: 886.3.5169213
2
LUMNDS827-Jan0408 Rev A.1
1.25 Gbps Single Mode Transceiver
C-13-1250AC-T(3)-SSC(2)
Connection Diagram
1. (Rx GND) 2. (Rx +) 3. (Rx-) 4. (SD) 5. (Rx Vcc) 6. (Tx Vcc) 7. (TX-) 8. (TX+) 9. (Tx GND)
NC
Top View
NC
Receiver Signal Ground Receiver Data Out Receiver Data Out Bar Signal Detect Receiver Power Supply Transmitter Power Supply Transmitter Data In Bar Transmitter Data In Transmitter Signal Ground
PIN 1 2 3 4 5 6 7 8 Warnings 9
Symbol RxGND RD+ RDSD RxVcc TxVcc TDTD+ TxGND
Notes Directly connect this pin to the receiver ground plane See recommended circuit schematic See recommended circuit schematic Active high on this indicates a received optical signal DC power for the receiver section DC power for the transmitter section See recommended circuit schematic See recommended circuit schematic Directly connect this pin to the transmitter ground plane
LUMINENTOIC.COM
20550 Nordhoff St. * Chatsworth, CA 91311 * tel: 818.773.9044 * fax: 818.576.9486 9F, No 81, Shui Lee Rd. * Hsinchu, Taiwan, R.O.C. * tel: 886.3.5169222 * fax: 886.3.5169213
3
LUMNDS827-Jan0408 Rev A.1
1.25 Gbps Single Mode Transceiver
C-13-1250AC-T(3)-SSC(2)
Recommended Circuit Schematic
98
765
432
1
TD + TD -
Z=50 Z=50
Z=50 Z=50
RD + RD SD
Tx Vcc Rx Vcc
No internal connection No internal connection
Notes: C1=C2=0.1F C3=C4=10F L1=L2=1H
Transceiver Top view
L1
Vcc
C3 L2 C4
C1
Rx Vcc
C2
Tx Vcc
The split-loaded terminations for ECL signals need to be located at the input of devices receiving those ECL signals. The power supply filtering is required for good EMI performance. Use short tracks from the inductor L1/L2 to the module Rx Vcc. A GND plane under the module is required for good EMI and sensitivity performance.
LUMINENTOIC.COM
20550 Nordhoff St. * Chatsworth, CA 91311 * tel: 818.773.9044 * fax: 818.576.9486 9F, No 81, Shui Lee Rd. * Hsinchu, Taiwan, R.O.C. * tel: 886.3.5169222 * fax: 886.3.5169213
4
LUMNDS827-Jan0408 Rev A.1
1.25 Gbps Single Mode Transceiver
C-13-1250AC-T(3)-SSC(2)
Package Diagram (10.4 mm SC transceiver assembly)
Top View
Front View
Units: mm
Side View
Rear View
Package Option: Blank, A = black case
LUMINENTOIC.COM
20550 Nordhoff St. * Chatsworth, CA 91311 * tel: 818.773.9044 * fax: 818.576.9486 9F, No 81, Shui Lee Rd. * Hsinchu, Taiwan, R.O.C. * tel: 886.3.5169222 * fax: 886.3.5169213
5
LUMNDS827-Jan0408 Rev A.1
1.25 Gbps Single Mode Transceiver
C-13-1250AC-T(3)-SSC(2)
Package Diagram (9.8 mm SC transceiver assembly)
Top View
Front View
Units: mm
x8
Side View
Package Option : B, E = Blue case C, D = Black case
Rear View
LUMINENTOIC.COM
20550 Nordhoff St. * Chatsworth, CA 91311 * tel: 818.773.9044 * fax: 818.576.9486 9F, No 81, Shui Lee Rd. * Hsinchu, Taiwan, R.O.C. * tel: 886.3.5169222 * fax: 886.3.5169213
6
LUMNDS827-Jan0408 Rev A.1
1.25 Gbps Single Mode Transceiver
C-13-1250AC-T(3)-SSC(2)
Ordering Information Available Options: C-13-1250AC-T(3)-SSC C-13-1250AC-T(3)-SSCA C-13-1250AC-T(3)-SSCB C-13-1250AC-T(3)-SSCC C-13-1250AC-T(3)-SSCD C-13-1250AC-T(3)-SSCE C-13-1250AC-T(3)-SSC2 C-13-1250AC-T(3)-SSC2A C-13-1250AC-T(3)-SSC2B C-13-1250AC-T(3)-SSC2C C-13-1250AC-T(3)-SSC2D C-13-1250AC-T(3)-SSC2E Part numbering Definition:
C-13-1250AC-T(3)-SSC-G5 C-13-1250AC-T(3)-SSCA-G5 C-13-1250AC-T(3)-SSCB-G5 C-13-1250AC-T(3)-SSCC-G5 C-13-1250AC-T(3)-SSCD-G5 C-13-1250AC-T(3)-SSCE-G5 C-13-1250AC-T(3)-SSC2-G5 C-13-1250AC-T(3)-SSC2A-G5 C-13-1250AC-T(3)-SSC2B-G5 C-13-1250AC-T(3)-SSC2C-G5 C-13-1250AC-T(3)-SSC2D-G5 C-13-1250AC-T(3)-SSC2E-G5
C - 13 - 1250AC - T(3) -
S SC TxPower Temperature and Package -RoHS
* 13 = Wavelength 1310nm * Communication protocol (1250 Mbps) AC = AC coupling for data input/output TTL Signal Detection output * T(3)= +3.3V Transceiver, FP * Single mode fiber * Connector options * Tx Power range Blank = -10 to -3 dBm 2 = -5 to 0 dBm * Temperature range and package Blank = commercial temperature(0 to 70 C), 10.4 mm, Black case A = industrial temperature(-40 to 85 C), 10.4 mm, Black case B = industrial temperature(-40 to 85 C), 9.8 mm, Blue case C = industrial temperature(-40 to 85 C), 9.8 mm, Black case D = commercial temperature(0 to 70 C), 9.8 mm, Black case E = commercial temperature(0 to 70 C), 9.8 mm, Blue case * RoHs Blank = RoHS non-compliant product G5 = RoHS 5/6-compliant product (lead exemption)
LUMINENTOIC.COM
20550 Nordhoff St. * Chatsworth, CA 91311 * tel: 818.773.9044 * fax: 818.576.9486 9F, No 81, Shui Lee Rd. * Hsinchu, Taiwan, R.O.C. * tel: 886.3.5169222 * fax: 886.3.5169213
7
LUMNDS827-Jan0408 Rev A.1
1.25 Gbps Single Mode Transceiver
C-13-1250AC-T(3)-SSC(2)
Warnings:
Handling Precautions: This device is susceptible to damage as a result of electrostatic discharge (ESD). A static free environment is highly recommended. Follow guidelines according to proper ESD procedures. Laser Safety: Radiation emitted by laser devices can be dangerous to human eyes. Avoid eye exposure to direct or indirect radiation.
Legal Notes:
IMPORTANT NOTICE! All information contained in this document is subject to change without notice, at LuminentOIC's sole and absolute discretion. LuminentOIC warrants performance of its products to current specifications only in accordance with the company's standard one-year warranty; however, specifications designated as "preliminary" are given to describe components only, and LuminentOIC expressly disclaims any and all warranties for said products, including express, implied, and statutory warranties, warranties of merchantability, fitness for a particular purpose, and non-infringement of proprietary rights. Please refer to the company's Terms and Conditions of Sale for further warranty information. LuminentOIC assumes no liability for applications assistance, customer product design, software performance, or infringement of patents, services, or intellectual property described herein. No license, either express or implied, is granted under any patent right, copyright, or intellectual property right, and LuminentOIC makes no representations or warranties that the product(s) described herein are free from patent, copyright, or intellectual property rights. Products described in this document are NOT intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. LuminentOIC customers using or selling products for use in such applications do so at their own risk and agree to fully defend and indemnify LuminentOIC for any damages resulting from such use or sale. THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROVIDED ON AN "AS IS" BASIS. Customer agrees that LuminentOIC is not liable for any actual, consequential, exemplary, or other damages arising directly or indirectly from any use of the information contained in this document. Customer must contact LuminentOIC to obtain the latest version of this publication to verify, before placing any order, that the information contained herein is current. (c) LuminentOIC, Inc. 2003 All rights reserved
LUMINENTOIC.COM
20550 Nordhoff St. * Chatsworth, CA 91311 * tel: 818.773.9044 * fax: 818.576.9486 9F, No 81, Shui Lee Rd. * Hsinchu, Taiwan, R.O.C. * tel: 886.3.5169222 * fax: 886.3.5169213
8
LUMNDS827-Jan0408 Rev A.1


▲Up To Search▲   

 
Price & Availability of C-13-1250AC-T3-SSC2A-G5

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X